Perfectly suited for brine pools, seawater and any other plants with high disinfection demands. Water/water heat exchanger, processed with the usual premium workmanship and care, state of the art welding. This premium heat exchanger has uncompromised resistance to corrosion, even at high salt levels in the pool water, and is therefore seawater proof. These heat exchangers offer maximum energy efficiency at minimal pressure loss. Like all other coiled tubing heat exchangers, they must be integrated in the bathing water circuit either directly or through the bypass-system.
Technical Information
| 42 kW
| 76 kW
| 105 kW
| 132 kW
|
heat capacity at 90° C
| 36.120 kcal/h
| 65.360 kcal/h
| 90.300 kcal/h
| 113.520 kcal/h
|
temperature difference
| 70°C = 0,6 kW/°C
| 70°C = 1,09 kW/°C
| 70°C = 1,5 kW/°C
| 70°C = 1,88 kW/°C
|
area
| 0,17 m2
| 0,35 m2
| 0,56 m2
| 0,79 m2
|
min. pump capacity primary
| 3 m3/h
| 4 m3/h
| 6 m3/h
| 5 m3/h
|
min. pump capacity secondary
| 12 m3/h
| 15 m3/h
| 18 m3/h
| 18 m3/h
|
pressure loss primary
| 0,18
| 0,22
| 0,40
| 0,42
|
pressure loss secondary
| 0,10 bar
| 0,18 bar
| 0,22 bar
| 0,27 bar
|
max. pressure primary 1000 kPa
|
10 bar |
10 bar | 10 bar
| 10 bar
|
max. pressure secondary 300 kPa
| 3 bar
| 3 bar
| 3 bar
| 3 bar
|
material: titanium lacquered RAL 9006
| ASTM / Gr.1
| ASTM / Gr.1
| ASTM / Gr.1
| ASTM / Gr.1
|
weight
| 2 kg
| 4 kg
| 6 kg
| 7,5 kg
|
A, mm
| 385
| 680
| 780
| 1050
|
B, mm
| D. 125
| D. 125
| D. 160
| D. 160
|
C, mm
| 205
| 495
| 590
| 820
|
E, " AG
| 1 1/2
| 1 1/2
| 2
| 2
|
F, "
| 3/4
| 1
| 1
| 1
|