Heat pump with energy class "A" for outdoor pools, inverter technology and quiet operation. It is specially designed to achieve good results in harsh climatic conditions (up to -20ºC outside air temperature). In addition, it works in energy saving mode to achieve better energy efficiency, reduces noise compared to other heat pumps and can be used throughout the year.
Specifications:
• "A" energy class that can save up to 33%.
• Inverter technology that automatically changes power settings so that the heat pump operates at optimum performance levels.
• Free application (iOS and Android) for remote control of the pump via WiFi and 3G / 4G networks.
• A quiet starter that prevents current waves when the compressor is running.
• Low outdoor operating temperature of -20 ° C, designed for cold operation.
• Defrost by cycle inversion . Faster defrosts.
• Heating and cooling modes thanks to the four-way valve.
• Electronic expansion valve for improved COP performance.
• R-410a Freon that does not damage the ozone layer.
• ABS plastic housing that prevents corrosion.
• Titanium exchanger , with twisted-tube to improve performance.
• Flow switch and presotates of high and low pressure.
Included accessories: Winter cover, anti-vibration brackets, drainage connection, waterproof screen, 10m screen connection cable, hydraulic connections and Modbus signal cable.
Technical characteristics
Model |
|
7 kW
single-phase |
10 kW
single-phase |
13 kW
single-phase |
Voltage |
V |
220 ~ 240V
50-60Hz |
220 ~ 240V
50-60Hz |
220 ~ 240V
50-60Hz |
Rated current |
A |
4.4 |
6.5 |
8.5 |
Minimum fuseA |
|
7 |
10 |
13 |
Indicative
water volume
(pool with thermal blanket) |
m³ Max. |
26 |
36 |
66 |
m³ Min. |
10 |
12 |
18 |
Nominal flow |
m³ / h |
2.5 |
3.0 |
4.0 |
Pressure loss |
Kpa |
12 |
12 |
14 |
No. of fans |
|
one |
one |
one |
Sound level |
dB (A) (1 m) |
40-50 |
40-52 |
40-54 |
T air 27 °
T water 26 ° |
Power (kW) |
7-3.1 |
10-2.3 |
13-3 |
Consumption (kW) |
1.01-0.26 |
1.49-0.14 |
1.94-0.19 |
COP |
15-6.9 |
16-6.7 |
16-6.7 |
T air 15 °
T water 26 ° |
Power (kW) |
5.1-2.5 |
7.1-1.9 |
9.6-2 |
Consumption (kW) |
1-0.38 |
1.4-0.25 |
1.84-0.26 |
COP |
7.9-5.1 |
8.0-5.1 |
8.0-5.2 |
Dimensions |
mm |
990x380x560 |
1050x440x709 |
Net weight |
kg |
54 |
68 |
78 |
Model |
|
17 kW
single-phase |
20 kW
single-phase |
26 kW
single-phase |
Voltage |
V |
220 ~ 240V
50-60Hz |
220 ~ 240V
50-60Hz |
220 ~ 240V
50-60Hz |
Rated current |
A |
11 |
13 |
17 |
Minimum fuse |
A |
16 |
20 |
26 |
Indicative
water volume
(pool with thermal blanket) |
m³ Max. |
86 |
122 |
135 |
m³ Min. |
28 |
58 |
68 |
Nominal flow |
m³ / h |
5.0 |
6.0 |
8.0 |
Fall loss pressure |
Kpa |
15 |
18 |
20 |
No. of fans |
|
one |
one |
two |
Sound level |
dB (A) (1 m) |
41-56 |
41-56 |
42-60 |
T air 27 °
T water 26 ° |
Power (kW) |
17-3.8 |
20-4.6 |
26-6.8 |
Consumption (kW) |
2.54-0.24 |
2.98-0.29 |
3.88-0.43 |
COP |
16-6.7 |
16-6.7 |
16-6.7 |
T air 15 °
T water 26 ° |
Power (kW) |
11.5-3 |
14-3 |
19-5.4 |
Consumption (kW) |
2.2-0.36 |
2.7-0.36 |
3.6-0.66 |
COP |
8.2-5.2 |
8.2-5.1 |
8.2-5.2 |
Dimensions |
mm |
1113x450x870 |
1050x460x1285 |
Net weight |
kg |
98 |
108 |
120 |
Model |
|
26 kW
three-phase |
35 kW
single-phase |
35 kW
three-phase |
Voltage |
V |
380V
50-60Hz |
220 ~ 240V
50-60Hz |
380V
50-60Hz |
Rated current |
A |
6.2 |
22.9 |
8.4 |
Minimum fuse |
A |
9 |
3. 4 |
13 |
Indicative
water volume
(pool with thermal blanket) |
m³ Max. |
135 |
160 |
160 |
m³ Min. |
68 |
78 |
78 |
Nominal flow |
m³ / h |
8.0 |
10.0 |
10.0 |
Fall loss pressure |
Kpa |
20 |
25 |
25 |
No. of fans |
|
two |
two |
two |
Sound level |
dB (A) (1 m) |
42-60 |
42-60 |
42-60 |
T air 27 °
T water 26 ° |
Power (kW) |
26-6.8 |
35-8 |
35-8 |
Consumption (kW) |
3.88-0.43 |
5.22-0.5 |
5.22-0.5 |
COP |
16-6.7 |
16-6.7 |
16-6.7 |
T air 15 °
T water 26 ° |
Power (kW) |
19-5.4 |
24-5.6 |
24-5.6 |
Consumption (kW) |
3.6-0.66 |
4.8-0.68 |
4.8-0.68 |
COP |
8.2-5.2 |
8.2-5 |
8.2-5 |
Dimensions |
mm |
1050x460x1285 |
Net weight |
kg |
120 |
130 |
130 |